Speak with a real person who will go out of the way to help!
The picture shown is for representative purposes only. The actual product delivered corresponds to the part number you ordered.
Texnite is not an authorized distributor, reseller, or representative of the products displayed or mentioned on this website. All product names, trademarks, brands, and logos used or referred to on this site remain the property of their respective owners. The depiction, description, or sale of products showcasing these names, trademarks, brands, and logos is solely for identification purposes and does not imply or intend to indicate any affiliation with or authorization by any rights holder.
Product is surplus. Manufacturer's warranties do NOT apply.
Allen Bradley 1336-B010-EOD-L3 Used Surplus
Allen Bradley- Part
- #1336-B010-EOD-L3
- Condition:
- Used
Technical Specifications for 1336-B010-EOD-L3
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number/Catalog No. | 1336-B010-E0D-L3 |
| Product Type | Adjustable Frequency AC Drive |
| Input Voltage | 380/415/460V AC |
| Hz | 50/60 |
| Phases | 3 |
| Amps Out | 17 |
| KVA Out @ 380V AC | 11.2 |
| KVA Out @ 415V AC | 12.2 |
| KVA Out at 460V AC | 13.5 |
| Enclosure Type | Open style (IP00) |
| Enclosure Amp Rating | 003, 005, 007, or 010 |
| Bulletin | 1336 |
| Option | 115 V AC Logic Interface Board. |
| Product Lifecycle Status* | Discontinued/Obsolete |
*The Allen Bradley 1336-B010-EOD-L3 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B010-EOD-L3 units instead of migration.
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number/Catalog No. | 1336-B010-E0D-L3 |
| Product Type | Adjustable Frequency AC Drive |
| Input Voltage | 380/415/460V AC |
| Hz | 50/60 |
| Phases | 3 |
| Amps Out | 17 |
| KVA Out @ 380V AC | 11.2 |
| KVA Out @ 415V AC | 12.2 |
| KVA Out at 460V AC | 13.5 |
| Enclosure Type | Open style (IP00) |
| Enclosure Amp Rating | 003, 005, 007, or 010 |
| Bulletin | 1336 |
| Option | 115 V AC Logic Interface Board. |
| Product Lifecycle Status* | Discontinued/Obsolete |
*The Allen Bradley 1336-B010-EOD-L3 has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B010-EOD-L3 units instead of migration.
sAbout 1336-B010-EOD-L3
The Rockwell Automation/Allen-Bradley 1336-B010-EOD-L3 is a Bulletin 1336 adjustable frequency drive. Drives in this series are microprocessor controlled, producing a three-phase Power With Modulation (PWM) variable frequency output and supplying an adjustable motor speed. Additionally, drives in the 1336 series, including the 1336-B010-EOD-L3, ensure that the induction motor being controlled reaches the maximum performance by providing a configurable frequency which is in line with the motor parameters. The 1336-B010-EOD-L3, as with other 1336 variable frequency drives, can be programmed digitally or by using a Local or Remote Control Panel or even by using optional devices which are interfaced with the 1336-B010-EOD-L3 through the serial communication port on the drive.
The operating voltage for the 1336-B010-EOD-L3 ranges between 380 and 460 Volts AC at a frequency range of 50 and 60 Hertz and its rated enclosure type should have an IP00 international protection rating. For the factory installed options, the 1336-B010-EOD-L3 comes with a +115 Volts AC Logic Interface Board. When installing the drive, as a rule of thumb, all incoming power should be locked out to prevent injury to personnel and damage to other components/devices. The power should only be connected when all other connections have been made and verified. But when disconnecting the 1336-B010-EOD-L3, the power should be the first thing that is disconnected. Apart from disconnecting the power to the drive, the bus indicator light should be allowed to switch off, which indicates that the bus does not have any residual active power. The +DC and –DC terminals on the terminal block (TB1) should also be checked to ensure that they have zero voltage.