The picture shown is for representative purposes only. The actual product delivered corresponds to the part number you ordered.
NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING
Texnite is not an authorized distributor, reseller, or representative of the products displayed or mentioned on this website. All product names, trademarks, brands, and logos used or referred to on this site remain the property of their respective owners. The depiction, description, or sale of products showcasing these names, trademarks, brands, and logos is solely for identification purposes and does not imply or intend to indicate any affiliation with or authorization by any rights holder.
Texnite is NOT an authorized distributor, affiliate or representative for the Manufacturer. Product is surplus. Manufacturer's warranties do NOT apply.
NUMERICAL OVERCURRENT-TIME PROTECT. RELAY SIPROTEC 7SJ602 OPTIONAL: MOTOR PROTECTION OPTIONAL: COMMUNICATION INTERFACE BINARY INPUT VOLTAGE:24 TO 250V MEASURING INPUTS(4 X I): IN= 1A SUPPLY VOLTAGE: DC 110 TO 250V, AC 115V, 230V TRIGGER LEVEL BINARY INPUT 88V FLUSH MOUNTING, SCREW TERMINALS (DIRECT WIRING/RING LUGS) LANGUAGE ENGLISCH, GERMAN, FRENCH, SPANISH, 50/60HZ IEC/ANSI, REGION WORLD SYSTEM PORT ON BOTTOM OF UNIT THERMO-BOX, ELECTRICAL RS485 WITHOUT COMMAND WITH FAULT RECORDING FUNCTIONALITY: TOC+ MOTOR PHASE OVERCURRENT (50/51): I>,I>>,IP,REVERSE INTERLOCKING, INDEPENDENT OF PHASE ROTATION, GROUND OVERCURRENT (50N/51N): IE>, IE>>,IEP, OVERLOAD PROTECTION WITH 2 TIME CONSTANTS (49), TRIP CIRCUIT SUPERVISION (74TC) BREAKER-FAILURE PROTECT. (50BF) COLD LOAD PICKUP, NEGATIVE SEQUENCE (46), MOTOR PROTECTION: START UP SUPERVERSION (48), UNDERCURRENT/LOSS OF LOAD MONITORING (37), RESTART INHIBIT (66/86) WITHOUT AUTOMATIC RECLOSING
QUICK DELIVERY
FREE SHIPPING
2 YEAR WARRANTY
EASY RETURNS
Questions?
Speak with a real person who will go out of the way to help!