Speak with a real person who will go out of the way to help!
The picture shown is for representative purposes only. The actual product delivered corresponds to the part number you ordered.
- 1370FFE
- DISCONTINUED BY MANUFACTURER
- FIELD SUPPLY MODULE
- INPUT VOLTAGE 230/460VAC 50/60HZ
- DC OUTPUT FIELD VOLTS 150/300 VDC
- 15 AMP
- FACTORY WARRANTY DOES NOT APPLY. TEXNITE 2-YEAR WARRANTY INCLUDED
Texnite is not an authorized distributor, reseller, or representative of the products displayed or mentioned on this website. All product names, trademarks, brands, and logos used or referred to on this site remain the property of their respective owners. The depiction, description, or sale of products showcasing these names, trademarks, brands, and logos is solely for identification purposes and does not imply or intend to indicate any affiliation with or authorization by any rights holder.
Product is surplus. Manufacturer's warranties do NOT apply.
Allen Bradley 1370-FFE Used Surplus
Allen Bradley- Part
- #1370-FFE
- Condition:
- Used
- 1370FFE
- DISCONTINUED BY MANUFACTURER
- FIELD SUPPLY MODULE
- INPUT VOLTAGE 230/460VAC 50/60HZ
- DC OUTPUT FIELD VOLTS 150/300 VDC
- 15 AMP
- FACTORY WARRANTY DOES NOT APPLY. TEXNITE 2-YEAR WARRANTY INCLUDED
Technical Specifications for 1370-FFE
| Brand | Allen-Bradley / Rockwell Automation |
| Series | 1370 Modules and Accessories |
| Part Number | 1370-FFE |
| Line voltage (nominal) | 230 Volts or 460 Volts AC |
| Phase | Three Phase |
| Line current | Maximum draw is 16 Amps RMS AC |
| Line frequency | 50 to 60 Hertz |
| DC output | 150 to 300 Volts DC |
| Current limit | 0 to 150% (adjustable) |
| Operational altitude | 1000 meters (3300 feet) |
| Relative humidity | 5 to 95% (non-condensing) |
| Operating temperature | 0 to 40 degrees Celsius (32 to 104 degrees Fahrenheit) |
| Storage temperature | 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit) |
| Brand | Allen-Bradley / Rockwell Automation |
| Series | 1370 Modules and Accessories |
| Part Number | 1370-FFE |
| Line voltage (nominal) | 230 Volts or 460 Volts AC |
| Phase | Three Phase |
| Line current | Maximum draw is 16 Amps RMS AC |
| Line frequency | 50 to 60 Hertz |
| DC output | 150 to 300 Volts DC |
| Current limit | 0 to 150% (adjustable) |
| Operational altitude | 1000 meters (3300 feet) |
| Relative humidity | 5 to 95% (non-condensing) |
| Operating temperature | 0 to 40 degrees Celsius (32 to 104 degrees Fahrenheit) |
| Storage temperature | 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit) |
About 1370-FFE
The 1370 series field supply module that is known as the 1370-FFE module is part of Series B of the power supply modules by Allen-Bradley/Rockwell Automation which offers a wide range of features such as the calibration of speed feedback signals, DC gain adjustment, and adjustment of the speed loop response. Also, the 1370 module has fault indicators on the front with LED illumination that signals if the malfunction is resolved or not. The wiring and installation process of the module are simple and the module provides protection from overloading, phase loss, and field loss. The 1370-FFE module requires a 3-phase power supply and its AC line voltage rating is 230 Volts AC or 460 Volts AC. In addition to that, the armature power supply is the 3-phase/full wave/6 pulse type and the AC line frequency is 50 to 60 Hertz.
The line current of the 1370-FFE module has a maximum draw of 16 Amps RMS AC. The module has potentiometers and terminal blocks. The armature current limit range is 0 to 100% of the rated armature current for continuous operation and it is up to 150% for 1-minute current. The 1370-FFE module has an adjustable current limit of 0 to 150% of the rated adjustable current and it operates with DC motors with the NEMA power supply code “C”. The manufacturer suggests that the 1370-FFE module operates at an ambient temperature range of 0 to 40 degrees Celsius (32 to 104 degrees Fahrenheit). The maximum storage temperature is 60 degrees Celsius (140 degrees Fahrenheit). Other ambient conditions include an operational altitude of 1000 meters (3300 feet) and a relative humidity level of 5 to 95% (non-condensing).