- 1336B015EAE
- DISCONTINUED BY MANUFACTURER
- AC DRIVE
- 1336 ADJUSTABLE FREQUENCY
- 460 VAC
- 50/60 HZ
- 11 KW / 15 HP
- 25 AMP
- IP20 / NEMA 1 ENCLOSURE
- FACTORY WARRANTY DOES NOT APPLY. TEXNITE 1-YEAR WARRANTY INCLUDED
Texnite is not an authorized distributor, reseller, or representative of the products displayed or mentioned on this website. All product names, trademarks, brands, and logos used or referred to on this site remain the property of their respective owners. The depiction, description, or sale of products showcasing these names, trademarks, brands, and logos is solely for identification purposes and does not imply or intend to indicate any affiliation with or authorization by any rights holder.
Product is surplus. Manufacturer's warranties do NOT apply.
Allen Bradley 1336-B015-EAE Used Surplus
Allen Bradley- 1336B015EAE
- DISCONTINUED BY MANUFACTURER
- AC DRIVE
- 1336 ADJUSTABLE FREQUENCY
- 460 VAC
- 50/60 HZ
- 11 KW / 15 HP
- 25 AMP
- IP20 / NEMA 1 ENCLOSURE
- FACTORY WARRANTY DOES NOT APPLY. TEXNITE 1-YEAR WARRANTY INCLUDED
QUICK DELIVERY
FREE SHIPPING
1 YEAR WARRANTY
EASY RETURNS
Reviews
Technical Specifications for 1336-B015-EAE
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1336-B015-EAE |
Product Type | Adjustable Frequency AC Drive |
Input Voltage | 380/415/460V AC |
Hz | 50/60 |
Phases | 3 |
Amps Out | 25 |
KVA Out at 380V AC | 16.5 |
KVA Out at 415V AC | 18 |
KVA Out at 460V AC | 20 |
Enclosure Type | NEMA Type 1 (IP20) |
Enclosure Amp Rating | 015 or 020 |
Bulletin | 1336 |
Product Lifecycle Status* | Discontinued/Obsolete |
*The Allen Bradley 1336-B015-EAE has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B015-EAE units instead of migration.
Manufacturer | Rockwell Automation |
Brand | Allen-Bradley |
Part Number/Catalog No. | 1336-B015-EAE |
Product Type | Adjustable Frequency AC Drive |
Input Voltage | 380/415/460V AC |
Hz | 50/60 |
Phases | 3 |
Amps Out | 25 |
KVA Out at 380V AC | 16.5 |
KVA Out at 415V AC | 18 |
KVA Out at 460V AC | 20 |
Enclosure Type | NEMA Type 1 (IP20) |
Enclosure Amp Rating | 015 or 020 |
Bulletin | 1336 |
Product Lifecycle Status* | Discontinued/Obsolete |
*The Allen Bradley 1336-B015-EAE has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1336-B015-EAE units instead of migration.
sAbout 1336-B015-EAE
The Rockwell Automation/Allen-Bradley 1336-B015-EAE is a constant torque AC drive. The drive measures 11 inches by 9 inches by 22 inches and it weighs 15.9 kilograms. The operating voltage for the 1336-B015-EAE is capped at 460 Volts AC with a frequency of 50/60 Hertz. Note that the operating voltage must be supplied by a three-phase power source. The 1336-B015-EAE has an output current of 25 Amps. The drive is supposed to be installed in a NEMA Type 1 enclosure which has an IP20 International Protection rating. The apparent output power rating for the 1336-B015-EAE is 16.5 kVA when operating at a voltage of 380 Volts AC, 18.0 kVA when operating at a voltage of 415 Volts AC, and 20.0 kVA when the operating voltage is 460 Volts AC.
The 1336-B015-EAE variable frequency drive belongs to the Allen-Bradley 1336 family of adjustable frequency drives. The 1336-B015-EAE, as with other drives with an enclosure type of Code E, has an enclosure current rating of 15 or 20 Amps. The 1336-B015-EAE allows for the interfacing of an optional local control panel which provides extra programming features such as jog, forward, reverse, start, and stop, with each having a dedicated pushbutton. However, the optional local control panel on the 1336-B015-EAE should not be considered to constitute a full operator station. Note that even when remote stop devices are used, the stop pushbutton on the local control panel remains functional. When the start pushbutton is pressed, the drive will start operating, accelerating the drive to the set speed but only if Parameter 21 is switched ON.